MOXA TCC-80. RS-232-RS485 converter

Forsiden Datautstyr Kontrollere Kontrollere MOXA TCC-80. RS-232-RS485 converter
Du må logge inn for å handle/se priser.
MOXA TCC-80. RS-232-RS485 converter (41673)

MOXA TCC-80. RS-232-RS485 converter

Varenr.:
41673
EAN:
5703431416734
  • Porter/kontakter Seriell
  • Eksterne porter Ja
  • Grensesnitt Seriell
  • Interne porter Nei
  • RAID Nei
Beskrivelse

TCC-80/80I


  Model No. Description
TCC-80 Port-powered RS-232 to RS-422/485 converter with 15 KV serial ESD protection and terminal block on the RS-422/485 side
TCC-80-DB9 Port-powered RS-232 to RS-422/485 converter with 15 KV serial ESD protection and DB9 male connector on the RS-422/485 side
TCC-80I Port-powered RS-232 to RS-422/485 converter with 15 KV serial ESD protection, terminal block on the RS-422/485 side, and 2.5 KV optical isolation
TCC-80I-DB9 Port-powered RS-232 to RS-422/485 converter with 15 KV serial ESD protection, DB9 male connector on the RS-422/485 side, and 2.5 KV optical isolation


Port-powered RS-232 to RS-422/485 with 2.5 KV isolation

The TCC-80/80I provides complete signal conversion between RS-232 and RS-422/485, without requiring an external power source. It supports both half duplex 2-wire RS-485 and full duplex 4-wire RS-422/485, either of which can be converted between RS-232's TxD and RxD lines. In addition,the TCC-80/80I's 15 KV ESD protection guards against damage from electrostatic discharge. The TCC-80I is the world's first high-speed, port-powered converter with 2.5 KV isolation.

Automatic data direction control is also provided for RS-485, in which the RS-485 driver is enabled automatically when the circuitry senses the TxD output from the RS-232 signal. This means that no programming effort is required to control the transmission direction of the RS-485 signal. Moreover, the TCC-80I patented LED port power indicator can let you check if TCC-80I is receiving enough power or not.

Port Power over RS-232
The RS-232 port of the TCC-80 is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD, RTS, or DTR line. Regardless of whether the signal is high or low, the TCC-80 can obtain enough power from the data/handshake line. However, external power can be used if the handshake line is not available, if the serial cable is too long, or if the RS-232 device is a low power device. For external power, a 5 to 12 VDC power supply can be connected using an adaptor or a USB power cord.

Optional External Power
Termination is a critical requirement for port-powered devices such as the TCC-80. In most circumstances, termination resistors are used if the RS-422/485 cable is longer than 100 m. Regardless of how much the data signal is dissipated, the termination resistors absorb more than 75 mW of power. In other words, if long distance RS-422/485 transmission or termination is required, then an external USB power cord or DC power supply should be used.

Port Power Dissipation
When installing a TCC-80 converter, it is important to pay attention to power consumption, RS-232 cable length, and RS-422/485 transmission distance. In general, the TCC-80 obtains 50 mW from the power source. Standard PC COM ports can provide 70 to 90 mW of power if the TxD, RTS, and DTR lines are connected. Moreover, the RS-232 cable should be shorter than 15 m (@ 9600 bps) to ensure that less power is lost from the host/device to the TCC-80. The remainder of the supplied power is used for transmitting the RS-422/485 signal.

Port Power and Optical Isolation
The RS-232 port of the TCC-80 is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD line. Electrical 2.5 KV isolation is achieved with a photo coupler that transforms the electrical signal into light, and then re-transforms the light back into an electrical signal on the other side. In this way, the two electrical circuits are completely isolated from each other. This also protects the devices from ground loop currents, reduces damage caused by data loss, and prevents damage to the communication interfaces.

LED Port Power Indicator
It's easy enough to test the serial device with a multimeter to determine that the serial device will provide enough power to the media converter. However, it's even easier to let the TCC-80I test the device for you. Simply connect the TCC-80I to the device's RS-232 port and set the SW4 switch to Test mode. If the patented port power LED indicator lights up, the TCC-80I is receiving enough power. If the LED does not light up, you will need to attach an external power source to the TCC-80I.

Features

  • External power source supported but not required
  • Compact size
  • Converts RS-422, and both 2-wire and 4-wire RS-485
  • RS-485 automatic data direction control
  • Automatic baudrate detection
  • 15 KV serial ESD protection
  • Built-in 120-ohm termination resistors
  • 2.5 KV isolation (for TCC-80I only)
  • LED port power indicator

Specifications:

RS-232 Side
Connector DB9 female
Signals RS-232: TxD, RxD, GND 
(Loop-back wiring: RTS to CTS, DTR to DSR and DCD)
RS-422/485 Side
Connector Terminal Block or DB9 male
Signals (interface selected by DIP switch) 
RS-422: TxD+, TxD-, RxD+, RxD-, GND 
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND 
RS-485-2w: Data+, Data-, GND
RS-485 Data Direction Control ADDC® (automatic data direction control)
Serial Communication
Baudrate 50 bps to 115.2 Kbps
ESD Protection 15 KV
Optical Isolation 2.5 KV rms for 1 minute (TCC-80I only)
Physical Characteristics
Housing ABS + PC
Dimensions 42 x 80 x 22 mm (1.65 x 3.15 x 0.87 in)
Weight 50 ± 5 g
Environmental Limits
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -20 to 75°C (-14 to 167°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Power Requirements
Source of Input Power RS-232 port (TxD, RTS, DTR) or power input jack
Input Voltage 5 to 12 VDC
Power Consumption TCC-80: 10 mA @ 5 V (with termination disabled) 
TCC-80I: 20 mA @ 5 V (with termination disabled)
Standards and Certifications
Safety UL 60950-1
EMC CE, FCC
EMI FCC Part 15 Subpart B Class B
EMS EN 61000-4-2 (ESD) Level 2,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
Green Product RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time 2,781,161 hrs
Database Telcordia (Bellcore), GB
Warranty
Warranty Period 5 years

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.